EBOSS Specifier Survey
eboss technical library
List/Grid

Flashings Subscribe to Flashings

E2/AS1: The End of Direct Fix Cladding?

E2/AS1: The End of Direct Fix Cladding?

I have studied the recent changes to the New Zealand Building Code’s (NZBC) Acceptable Solution E2/AS1 for Clause E2 External Moisture that came into effect in August 2011.  After an… Read more »

Cladding Junctions and Weathertightness

Cladding Junctions and Weathertightness

Most homes and buildings these days have multiple claddings. Weathertightness and aesthetic detailing problems arise where two claddings meet. At Flashman, we have been aware of this flashing issue for… Read more »

Best Practice Drawings on New Flashman Website

Best Practice Drawings on New Flashman Website

Flashman have completely redesigned their website to provide you with over 150 best practice weather-tightness details around aluminium windows and doors. They have also added a number of best practice… Read more »

Ensure Fast Enclosure with Flashman Window and Door Flashings

Ensure Fast Enclosure with Flashman Window and Door Flashings

Born out of Christchurch, Flashmans’ Branz Appraised Flashman Flashing System comprises a full window and door flashing system that is installed by Flashman Distributors/Installers. The System is precision cut off site and is fitted as soon as the windows and doors are installed…

Flashman Specified on Pioneering Uni Tower Blocks

Flashman Specified on Pioneering Uni Tower Blocks

Flashman were approached by a large construction company to provide a solution for the window flashings on a proposed project of three 14 storey tower blocks to serve as accommodation… Read more »

Flashman Expanding in all Directions

Flashman Expanding in all Directions

Flashman has moved to a new high level of activity with branches now in Northland, Auckland, Wellington, Manawatu, Whanganui, Nelson, Tasman, Blenheim, Canterbury, Westland, Otago and Southland. They also have… Read more »

Sealants as Flashing a Poor Option

Sealants as Flashing a Poor Option

Sealants are still the default flashing around windows and doors. This is very poor practice and contrary to all advice on how to apply sealants. Let’s have a look at… Read more »

Leaking Sacramento Apartments – What Has Changed?

Leaking Sacramento Apartments – What Has Changed?

I recently visited the notorious Sacramento Apartments where extensive remediation work is underway. I looked at the repairs and asked, “What has changed?”  The answer I received was: “Nothing, really.”… Read more »

Raking Heads and Sills on Aluminium Window and Door Flashing

Raking Heads and Sills on Aluminium Window and Door Flashing

Having seen a wide range of failed aluminium window and door flashing I strongly advise not to design raking window or door heads unless the head is hard up to… Read more »

Flashman Rebuild Website for Better Access to Technical Information

Flashman Rebuild Website for Better Access to Technical Information

Flashman has just completed a full rebuild of their website. Architects, designers and specifiers will find the site simpler, cleaner and providing faster access to essential information including technical drawings…. Read more »